Never sever non-cluster database; write more read-only documentation

Summary:
Ref T4571. Write more of the missing documentation sections and clarify a few things.

Since the "replicating master" check needs a special permission, imposes a performance penalty, is probably very difficult to misconfigure, and likely not a big deal anyway, just drop the idea of trying to automatically detect + prevent it. We still show if it's an issue on the status page, provided we have permission to check.

When you don't have any cluster databases configured, never stop trying to connect to the default master database. We might want to do this eventually as load reduction, but just don't muddy the waters too much for now while things stabilize.

Test Plan:
  - Tested functionality in cluster, non-cluster, and degraded-cluster modes.
  - Used status console to monitor a health check cycle.
  - Read docs.

Reviewers: chad

Reviewed By: chad

Maniphest Tasks: T4571

Differential Revision: https://secure.phabricator.com/D15679
This commit is contained in:
epriestley 2016-04-11 05:26:45 -07:00
parent ebff07d019
commit ac35246d0d
4 changed files with 220 additions and 34 deletions

View file

@ -35,6 +35,8 @@ final class PhabricatorConfigClusterDatabasesController
$rows = array(); $rows = array();
foreach ($databases as $database) { foreach ($databases as $database) {
$messages = array();
if ($database->getIsMaster()) { if ($database->getIsMaster()) {
$role_icon = id(new PHUIIconView()) $role_icon = id(new PHUIIconView())
->setIcon('fa-database sky') ->setIcon('fa-database sky')
@ -125,6 +127,9 @@ final class PhabricatorConfigClusterDatabasesController
} else { } else {
$health_icon = id(new PHUIIconView()) $health_icon = id(new PHUIIconView())
->setIcon('fa-times red'); ->setIcon('fa-times red');
$messages[] = pht(
'UNHEALTHY: This database has failed recent health checks. Traffic '.
'will not be sent to it until it recovers.');
} }
$health_count = pht( $health_count = pht(
@ -138,8 +143,6 @@ final class PhabricatorConfigClusterDatabasesController
$health_count, $health_count,
); );
$messages = array();
$conn_message = $database->getConnectionMessage(); $conn_message = $database->getConnectionMessage();
if ($conn_message) { if ($conn_message) {
$messages[] = $conn_message; $messages[] = $conn_message;

View file

@ -22,6 +22,10 @@ This configuration is complex, and many installs do not need to pursue it.
Phabricator can not currently be configured into a multi-master mode, nor can Phabricator can not currently be configured into a multi-master mode, nor can
it be configured to automatically promote a replica to become the new master. it be configured to automatically promote a replica to become the new master.
If you lose the master, Phabricator can degrade automatically into read-only
mode and remain available, but can not fully recover without operational
intervention unless the master recovers on its own.
Setting up MySQL Replication Setting up MySQL Replication
============================ ============================
@ -59,17 +63,109 @@ The other MySQL connection configuration options (`mysql.port`, `mysql.user`,
`mysql.pass`) are used only to provide defaults. `mysql.pass`) are used only to provide defaults.
Once you've configured this option, restart Phabricator for the changes to take Once you've configured this option, restart Phabricator for the changes to take
effect, then continue to "Monitoring and Testing" to verify the configuration. effect, then continue to "Monitoring Replicas" to verify the configuration.
Monitoring and Testing Monitoring Replicas
====================== ===================
You can monitor replicas in {nav Config > Cluster Databases}. This interface You can monitor replicas in {nav Config > Cluster Databases}. This interface
shows you a quick overview of replicas and their health, and can detect some shows you a quick overview of replicas and their health, and can detect some
common issues with replication. common issues with replication.
TODO: Write more stuff here. The table on this page shows each database and current status.
NOTE: This page runs its diagnostics //from the web server that is serving the
request//. If you are recovering from a disaster, the view this page shows
may be partial or misleading, and two requests served by different servers may
see different views of the cluster.
**Connection**: Phabricator tries to connect to each configured database, then
shows the result in this column. If it fails, a brief diagnostic message with
details about the error is shown. If it succeeds, the column shows a rough
measurement of latency from the current webserver to the database.
**Replication**: This is a summary of replication status on the database. If
things are properly configured and stable, the replicas should be actively
replicating and no more than a few seconds behind master, and the master
should //not// be replicating from another database.
To report this status, the user Phabricator is connecting as must have the
`REPLICATION CLIENT` privilege (or the `SUPER` privilege) so it can run the
`SHOW SLAVE STATUS` command. The `REPLICATION CLIENT` privilege only enables
the user to run diagnostic commands so it should be reasonable to grant it in
most cases, but it is not required. If you choose not to grant it, this page
can not show any useful diagnostic information about replication status but
everything else will still work.
If a replica is more than a second behind master, this page will show the
current replication delay. If the replication delay is more than 30 seconds,
it will report "Slow Replication" with a warning icon.
If replication is delayed, data is at risk: if you lose the master and can not
later recover it (for example, because a meteor has obliterated the datacenter
housing the physical host), data which did not make it to the replica will be
lost forever.
Beyond the risk of data loss, any read-only traffic sent to the replica will
see an older view of the world which could be confusing for users: it may
appear that their data has been lost, even if it is safe and just hasn't
replicated yet.
Phabricator will attempt to prevent clients from seeing out-of-date views, but
sometimes sending traffic to a delayed replica is the best available option
(for example, if the master can not be reached).
**Health**: This column shows the result of recent health checks against the
server. After several checks in a row fail, Phabricator will mark the server
as unhealthy and stop sending traffic to it until several checks in a row
later succeed.
Note that each web server tracks database health independently, so if you have
several servers they may have different views of database health. This is
normal and not problematic.
For more information on health checks, see "Unreachable Masters" below.
**Messages**: This column has additional details about any errors shown in the
other columns. These messages can help you understand or resolve problems.
Testing Replicas
================
To test that your configuration can survive a disaster, turn off the master
database. Do this with great ceremony, making a cool explosion sound as you
run the `mysqld stop` command.
If things have been set up properly, Phabricator should degrade to a temporary
read-only mode immediately. After a brief period of unresponsiveness, it will
degrade further into a longer-term read-only mode. For details on how this
works interanlly, see "Unreachable Masters" below.
Once satisfied, turn the master back on. After a brief delay, Phabricator
should recognize that the master is healthy again and recover fully.
Throughout this process, the {nav Cluster Databases} console will show a
current view of the world from the perspective of the web server handling the
request. You can use it to monitor state.
You can perform a more narrow test by enabling `cluster.read-only` in
configuration. This will put Phabricator into read-only mode immediately
without turning off any databases.
You can use this mode to understand which capabilities will and will not be
available in read-only mode, and make sure any information you want to remain
accessible in a disaster (like wiki pages or contact information) is really
accessible.
See the next section, "Degradation to Read Only Mode", for more details about
when, why, and how Phabricator degrades.
If you run custom code or extensions, they may not accommodate read-only mode
properly. You should specifically test that they function correctly in
read-only mode and do not prevent you from accessing important information.
Degradation to Read-Only Mode Degradation to Read-Only Mode
============================= =============================
@ -78,8 +174,8 @@ Phabricator will degrade to read-only mode when any of these conditions occur:
- you turn it on explicitly; - you turn it on explicitly;
- you configure cluster mode, but don't set up any masters; - you configure cluster mode, but don't set up any masters;
- the master is misconfigured and unsafe to write to; or - the master can not be reached while handling a request; or
- the master is unreachable. - recent attempts to connect to the master have consistently failed.
When Phabricator is running in read-only mode, users can still read data and When Phabricator is running in read-only mode, users can still read data and
browse and clone repositories, but they can not edit, update, or push new browse and clone repositories, but they can not edit, update, or push new
@ -99,20 +195,9 @@ but disabling the master, or by not specifying any host as a master. This may
be more convenient than turning it on explicitly during the course of be more convenient than turning it on explicitly during the course of
operations work. operations work.
Before writing to a master, Phabricator will verify that the host is not If Phabricator is unable to reach the master database, it will degrade into
configured as a replica. This is a safety feature to prevent data loss if your read-only mode automatically. See "Unreachable Masters" below for details on
MySQL and Phabricator configurations disagree about replica configuration. If how this process works.
your `master` is currently replicating from another host, Phabricator will
treat it as a `replica` instead and implicitly degrade into read-only mode.
Finally, if Phabricator is unable to reach the master, it will degrade into
read-only mode. For details on how Phabricator determines that a master is
unreachable, see "Unreachable Masters" below.
If a master becomes unreachable, this normally corresponds to loss of the
master host, a severed network link, or some other sort of disaster.
Phabricator will degrade and continue operating in read-only mode until the
master recovers or operations personnel can assess the situation and intervene.
If you end up in a situation where you have lost the master and can not get it If you end up in a situation where you have lost the master and can not get it
back online (or can not restore it quickly) you can promote a replica to become back online (or can not restore it quickly) you can promote a replica to become
@ -122,7 +207,7 @@ the new master. See the next section, "Promoting a Replica", for details.
Promoting a Replica Promoting a Replica
=================== ===================
TODO: Write this, too. TODO: Write this section.
Unreachable Masters Unreachable Masters
@ -131,7 +216,67 @@ Unreachable Masters
This section describes how Phabricator determines that a master has been lost, This section describes how Phabricator determines that a master has been lost,
marks it unreachable, and degrades into read-only mode. marks it unreachable, and degrades into read-only mode.
TODO: For now, it doesn't. Phabricator degrades into read-only mode automatically in two ways: very
briefly in response to a single connection failure, or more permanently in
response to a series of connection failures.
In the first case, if a request needs to connect to the master but is not able
to, Phabricator will temporarily degrade into read-only mode for the remainder
of that request. The alternative is to fail abruptly, but Phabricator can
sometimes degrade successfully and still respond to the user's request, so it
makes an effort to finish serving the request from replicas.
If the request was a write (like posting a comment) it will fail anyway, but
if it was a read that did not actually need to use the master it may succeed.
This temporary mode is intended to recover as gracefully as possible from brief
interruptions in service (a few seconds), like a server being restarted, a
network link becoming temporarily unavailable, or brief periods of load-related
disruption. If the anomaly is temporary, Phabricator should recover immediately
(on the next request once service is restored).
This mode can be slow for users (they need to wait on connection attempts to
the master which fail) and does not reduce load on the master (requests still
attempt to connect to it).
The second way Phabricator degrades is by running periodic health checks
against databases, and marking them unhealthy if they fail over a longer period
of time. This mechanism is very similar to the health checks that most HTTP
load balancers perform against web servers.
If a database fails several health checks in a row, Phabricator will mark it as
unhealthy and stop sending all traffic (except for more health checks) to it.
This improves performance during a service interruption and reduces load on the
master, which may help it recover from load problems.
You can monitor the status of health checks in the {nav Cluster Databases}
console. The "Health" column shows how many checks have run recently and
how many have succeeded.
Health checks run every 3 seconds, and 5 checks in a row must fail or succeed
before Phabricator marks the database as healthy or unhealthy, so it will
generally take about 15 seconds for a database to change state after it goes
down or comes up.
If all of the recent checks fail, Phabricator will mark the database as
unhealthy and stop sending traffic to it. If the master was the database that
was marked as unhealthy, Phabricator will actively degrade into read-only mode
until it recovers.
This mode only attempts to connect to the unhealthy database once every few
seconds to see if it is recovering, so performance will be better on average
(users rarely need to wait for bad connections to fail or time out) and the
datbase will receive less load.
Once all of the recent checks succeed, Phabricator will mark the database as
healthy again and continue sending traffic to it.
Health checks are tracked individually for each web server, so some web servers
may see a host as healthy while others see it as unhealthy. This is normal, and
can accurately reflect the state of the world: for example, the link between
datacenters may have been lost, so hosts in one datacenter can no longer see
the master, while hosts in the other datacenter still have a healthy link to
it.
Backups Backups

View file

@ -52,6 +52,7 @@ final class PhabricatorDatabaseHealthRecord
* the state. * the state.
*/ */
public function getRequiredEventCount() { public function getRequiredEventCount() {
// NOTE: If you change this value, update the "Cluster: Databases" docs.
return 5; return 5;
} }
@ -60,6 +61,7 @@ final class PhabricatorDatabaseHealthRecord
* Seconds to wait between health checks. * Seconds to wait between health checks.
*/ */
public function getHealthCheckFrequency() { public function getHealthCheckFrequency() {
// NOTE: If you change this value, update the "Cluster: Databases" docs.
return 3; return 3;
} }

View file

@ -14,6 +14,7 @@ final class PhabricatorDatabaseRef
const REPLICATION_SLOW = 'replica-slow'; const REPLICATION_SLOW = 'replica-slow';
const KEY_REFS = 'cluster.db.refs'; const KEY_REFS = 'cluster.db.refs';
const KEY_INDIVIDUAL = 'cluster.db.individual';
private $host; private $host;
private $port; private $port;
@ -21,6 +22,7 @@ final class PhabricatorDatabaseRef
private $pass; private $pass;
private $disabled; private $disabled;
private $isMaster; private $isMaster;
private $isIndividual;
private $connectionLatency; private $connectionLatency;
private $connectionStatus; private $connectionStatus;
@ -145,6 +147,15 @@ final class PhabricatorDatabaseRef
return $this->replicaDelay; return $this->replicaDelay;
} }
public function setIsIndividual($is_individual) {
$this->isIndividual = $is_individual;
return $this;
}
public function getIsIndividual() {
return $this->isIndividual;
}
public static function getConnectionStatusMap() { public static function getConnectionStatusMap() {
return array( return array(
self::STATUS_OKAY => array( self::STATUS_OKAY => array(
@ -207,6 +218,18 @@ final class PhabricatorDatabaseRef
return $refs; return $refs;
} }
public static function getLiveIndividualRef() {
$cache = PhabricatorCaches::getRequestCache();
$ref = $cache->getKey(self::KEY_INDIVIDUAL);
if (!$ref) {
$ref = self::newIndividualRef();
$cache->setKey(self::KEY_INDIVIDUAL, $ref);
}
return $ref;
}
public static function newRefs() { public static function newRefs() {
$refs = array(); $refs = array();
@ -339,6 +362,14 @@ final class PhabricatorDatabaseRef
} }
public function isSevered() { public function isSevered() {
// If we only have an individual database, never sever our connection to
// it, at least for now. It's possible that using the same severing rules
// might eventually make sense to help alleviate load-related failures,
// but we should wait for all the cluster stuff to stabilize first.
if ($this->getIsIndividual()) {
return false;
}
if ($this->didFailToConnect) { if ($this->didFailToConnect) {
return true; return true;
} }
@ -402,16 +433,7 @@ final class PhabricatorDatabaseRef
$refs = self::getLiveRefs(); $refs = self::getLiveRefs();
if (!$refs) { if (!$refs) {
$conf = PhabricatorEnv::newObjectFromConfig( return self::getLiveIndividualRef();
'mysql.configuration-provider',
array(null, 'w', null));
return id(new self())
->setHost($conf->getHost())
->setPort($conf->getPort())
->setUser($conf->getUser())
->setPass($conf->getPassword())
->setIsMaster(true);
} }
$master = null; $master = null;
@ -427,6 +449,20 @@ final class PhabricatorDatabaseRef
return null; return null;
} }
public static function newIndividualRef() {
$conf = PhabricatorEnv::newObjectFromConfig(
'mysql.configuration-provider',
array(null, 'w', null));
return id(new self())
->setHost($conf->getHost())
->setPort($conf->getPort())
->setUser($conf->getUser())
->setPass($conf->getPassword())
->setIsIndividual(true)
->setIsMaster(true);
}
public static function getReplicaDatabaseRef() { public static function getReplicaDatabaseRef() {
$refs = self::getLiveRefs(); $refs = self::getLiveRefs();