Summary: Fixes T4881.
Test Plan: made a config change, saw the issue, restarted daemons and it went away
Reviewers: epriestley
Reviewed By: epriestley
Subscribers: epriestley, Korvin
Maniphest Tasks: T4881
Differential Revision: https://secure.phabricator.com/D10339
Summary:
Fixes T5855. Adds a `--graceful N` flag to `phd stop` and `phd restart`.
`phd` will send SIGINT, wait `N` seconds, SIGTERM, wait 15 seconds, and SIGKILL. By default, `N` is 15.
Test Plan:
- Ran `bin/phd debug ...` and used `^C` to interrupt daemons. Saw graceful shutdown behavior, and abrupt termination on multiple `^C`.
- Ran `bin/phd start`, `bin/phd stop` and `bin/phd restart` with `--graceful` set to various things, notably `0`. Saw graceful shutdowns on the CLI and in the web UI. With `0`, abrupt shutdowns.
Reviewers: btrahan, hach-que
Reviewed By: hach-que
Subscribers: epriestley
Maniphest Tasks: T5855
Differential Revision: https://secure.phabricator.com/D10228
Summary:
Ref T4209. Unifies the local (`./bin/phd status`) and global (`./bin/phd status --all`) view into a single table. This generally makes it easy to administer daemons running across multiple hosts.
Depends on D9606.
Test Plan:
```
> sudo ./bin/phd status
ID Host PID Started Daemon Arguments
38 localhost 2282 Jun 18 2014, 7:52:56 AM PhabricatorRepositoryPullLocalDaemon
39 localhost 2289 Jun 18 2014, 7:52:57 AM PhabricatorGarbageCollectorDaemon
40 localhost 2294 Jun 18 2014, 7:52:57 AM PhabricatorTaskmasterDaemon
41 localhost 2314 Jun 18 2014, 7:52:58 AM PhabricatorTaskmasterDaemon
42 localhost 2319 Jun 18 2014, 7:52:59 AM PhabricatorTaskmasterDaemon
43 localhost 2328 Jun 18 2014, 7:53:00 AM PhabricatorTaskmasterDaemon
44 localhost 2354 Jun 18 2014, 7:53:08 AM PhabricatorRepositoryPullLocalDaemon X --not Y
```
Reviewers: #blessed_reviewers, epriestley
Reviewed By: #blessed_reviewers, epriestley
Subscribers: epriestley, Korvin
Maniphest Tasks: T4209
Differential Revision: https://secure.phabricator.com/D9607
Summary:
Ref T3675. Some of these listeners shouldn't do their thing if the viewer doesn't have access to an application (for example, users without access to Differential should not be able to "Edit Tasks"). Set the stage for that:
- Introduce `PhabricatorEventListener`, which has an application.
- Populate this for event listeners installed by applications.
- Rename the "PeopleMenu" listeners to "ActionMenu" listeners, which better describes their modern behavior.
This doesn't actually change any behaviors.
Test Plan: Viewed Maniphest, Differntial, People.
Reviewers: btrahan, chad
Reviewed By: btrahan
CC: aran
Maniphest Tasks: T3675
Differential Revision: https://secure.phabricator.com/D7364
Summary: Ref T1670. Use events and direct database writes instead of Conduit. Deprecate the Conduit methods.
Test Plan: Ran daemons, used the console to review daemon event logs.
Reviewers: btrahan
Reviewed By: btrahan
CC: aran
Maniphest Tasks: T1670
Differential Revision: https://secure.phabricator.com/D6536