1
0
Fork 0
mirror of https://we.phorge.it/source/phorge.git synced 2024-11-15 11:22:40 +01:00
Commit graph

10 commits

Author SHA1 Message Date
Joshua Spence
321c61a853 Remove daemon envHash and envInfo
Summary: Ref T7053. Remove the `envHash` and `envInfo` fields, which are no longer used now that the daemons restart automagically. Depends on D14458.

Test Plan: Saw no more setup issues.

Reviewers: #blessed_reviewers, epriestley

Reviewed By: #blessed_reviewers, epriestley

Subscribers: tycho.tatitscheff, epriestley

Maniphest Tasks: T7053

Differential Revision: https://secure.phabricator.com/D14446
2015-11-11 08:54:45 +11:00
epriestley
a354e5fa6b Track daemon unique IDs in Phabricator daemon logs
Summary:
Ref T7352. We were previously identifying things by `<daemonClass, overseerPID, startTime>` but that's not unique in a world where one overseer can run multiple daemons.

We already have an internal "daemonID", it just doesn't get written into the DB right now.

Start writing it, then use it to clean up `phd status`.

Test Plan: Ran `phd status`, got more accurate/useful output than previously.

Reviewers: btrahan

Reviewed By: btrahan

Subscribers: epriestley

Maniphest Tasks: T7352

Differential Revision: https://secure.phabricator.com/D11865
2015-02-24 14:50:37 -08:00
epriestley
6771a70499 Update Phabricator for DaemonOverseer vs DaemonHandle split
Summary: Ref T7352. A couple of the APIs changed slightly with D11851.

Test Plan: See D11851.

Reviewers: btrahan

Reviewed By: btrahan

Subscribers: epriestley

Maniphest Tasks: T7352

Differential Revision: https://secure.phabricator.com/D11852
2015-02-24 14:50:25 -08:00
epriestley
74ea59235a Make the "daemons and web have different config" warning more specific
Summary:
I'm hitting this in the cluster and couldn't figure it out after staring at it for a couple minutes. Produce a better error.

This dumps a hash of each configuration key value which is set to a non-default value into the daemon log. This is much more compact than the full config, and doesn't spread secrets around, so it seems like a good balance between providing information and going crazy with it.

Test Plan: {F284139}

Reviewers: btrahan

Reviewed By: btrahan

Subscribers: epriestley

Differential Revision: https://secure.phabricator.com/D11699
2015-02-05 14:07:35 -08:00
Fabian Stelzer
2fedb6f941 Start phd daemons as the correctly configured user and refuse otherwise
Summary:
Fixes T5196
If no phd.user is configured the behaviour is unchanged besides printing a warning when run as root (Usually i would add an exit(1) here but that would break existing installs who do that).
If phd.user is set and the current user is root it will run the daemon as: su USER -c "command" (I'm not sure if this works for every platform needed)
Otherwise it will refuse to start if configured and current user mismatch.

Test Plan: Stopped & Started phd daemon with various users and different phd.user settings including root

Reviewers: #blessed_reviewers, epriestley

Reviewed By: #blessed_reviewers, epriestley

Subscribers: vinzent, epriestley

Maniphest Tasks: T5196

Differential Revision: https://secure.phabricator.com/D11036
2014-12-23 08:15:51 -08:00
Bob Trahan
6f246bd351 Daemons - add a config check for out of date daemon environment
Summary: Fixes T4881.

Test Plan: made a config change, saw the issue, restarted daemons and it went away

Reviewers: epriestley

Reviewed By: epriestley

Subscribers: epriestley, Korvin

Maniphest Tasks: T4881

Differential Revision: https://secure.phabricator.com/D10339
2014-08-22 14:52:36 -07:00
epriestley
9309723ac4 Send graceful shutdown signals to daemons in Phabricator
Summary:
Fixes T5855. Adds a `--graceful N` flag to `phd stop` and `phd restart`.

`phd` will send SIGINT, wait `N` seconds, SIGTERM, wait 15 seconds, and SIGKILL. By default, `N` is 15.

Test Plan:
  - Ran `bin/phd debug ...` and used `^C` to interrupt daemons. Saw graceful shutdown behavior, and abrupt termination on multiple `^C`.
  - Ran `bin/phd start`, `bin/phd stop` and `bin/phd restart` with `--graceful` set to various things, notably `0`. Saw graceful shutdowns on the CLI and in the web UI. With `0`, abrupt shutdowns.

Reviewers: btrahan, hach-que

Reviewed By: hach-que

Subscribers: epriestley

Maniphest Tasks: T5855

Differential Revision: https://secure.phabricator.com/D10228
2014-08-11 20:18:31 -07:00
Joshua Spence
f52fbf6117 Unify the local and global view for ./bin/phd status.
Summary:
Ref T4209. Unifies the local (`./bin/phd status`) and global (`./bin/phd status --all`) view into a single table. This generally makes it easy to administer daemons running across multiple hosts.

Depends on D9606.

Test Plan:
```
> sudo ./bin/phd status
ID Host      PID  Started                 Daemon                               Arguments
38 localhost 2282 Jun 18 2014, 7:52:56 AM PhabricatorRepositoryPullLocalDaemon
39 localhost 2289 Jun 18 2014, 7:52:57 AM PhabricatorGarbageCollectorDaemon
40 localhost 2294 Jun 18 2014, 7:52:57 AM PhabricatorTaskmasterDaemon
41 localhost 2314 Jun 18 2014, 7:52:58 AM PhabricatorTaskmasterDaemon
42 localhost 2319 Jun 18 2014, 7:52:59 AM PhabricatorTaskmasterDaemon
43 localhost 2328 Jun 18 2014, 7:53:00 AM PhabricatorTaskmasterDaemon
44 localhost 2354 Jun 18 2014, 7:53:08 AM PhabricatorRepositoryPullLocalDaemon X --not Y
```

Reviewers: #blessed_reviewers, epriestley

Reviewed By: #blessed_reviewers, epriestley

Subscribers: epriestley, Korvin

Maniphest Tasks: T4209

Differential Revision: https://secure.phabricator.com/D9607
2014-06-18 11:44:52 +10:00
epriestley
d66972c9f2 Tie application event listeners to the applications they listen for
Summary:
Ref T3675. Some of these listeners shouldn't do their thing if the viewer doesn't have access to an application (for example, users without access to Differential should not be able to "Edit Tasks"). Set the stage for that:

  - Introduce `PhabricatorEventListener`, which has an application.
  - Populate this for event listeners installed by applications.
  - Rename the "PeopleMenu" listeners to "ActionMenu" listeners, which better describes their modern behavior.

This doesn't actually change any behaviors.

Test Plan: Viewed Maniphest, Differntial, People.

Reviewers: btrahan, chad

Reviewed By: btrahan

CC: aran

Maniphest Tasks: T3675

Differential Revision: https://secure.phabricator.com/D7364
2013-10-21 17:00:21 -07:00
epriestley
794dc0151a Use events rather than Conduit to report daemon status in Phabricator
Summary: Ref T1670. Use events and direct database writes instead of Conduit. Deprecate the Conduit methods.

Test Plan: Ran daemons, used the console to review daemon event logs.

Reviewers: btrahan

Reviewed By: btrahan

CC: aran

Maniphest Tasks: T1670

Differential Revision: https://secure.phabricator.com/D6536
2013-07-23 12:10:02 -07:00