Summary: Ref T5655. Some discussion in D9839. Generally speaking, `Phabricator{$name}Application` is clearer than `PhabricatorApplication{$name}`.
Test Plan:
# Pinned and uninstalled some applications.
# Applied patch and performed migrations.
# Verified that the pinned applications were still pinned and that the uninstalled applications were still uninstalled.
# Performed a sanity check on the database contents.
Reviewers: btrahan, epriestley, #blessed_reviewers
Reviewed By: epriestley, #blessed_reviewers
Subscribers: hach-que, epriestley, Korvin
Maniphest Tasks: T5655
Differential Revision: https://secure.phabricator.com/D9982
Summary:
While we mostly have reasonable effective object accessibility when you lock a user out of an application, it's primarily enforced at the controller level. Users can still, e.g., load the handles of objects they can't actually see. Instead, lock the queries to the applications so that you can, e.g., never load a revision if you don't have access to Differential.
This has several parts:
- For PolicyAware queries, provide an application class name method.
- If the query specifies a class name and the user doesn't have permission to use it, fail the entire query unconditionally.
- For handles, simplify query construction and count all the PHIDs as "restricted" so we get a UI full of "restricted" instead of "unknown" handles.
Test Plan:
- Added a unit test to verify I got all the class names right.
- Browsed around, logged in/out as a normal user with public policies on and off.
- Browsed around, logged in/out as a restricted user with public policies on and off. With restrictions, saw all traces of restricted apps removed or restricted.
Reviewers: btrahan
Reviewed By: btrahan
CC: aran
Differential Revision: https://secure.phabricator.com/D7367
Summary:
- Add GC support to conduit logs.
- Add Query support to conduit logs.
- Record the actual user PHID.
- Show client name.
- Support querying by specific method, so I can link to this from a setup issue.
@wez, this migration may not be fast. It took about 8 seconds for me to migrate 800,000 rows in the `conduit_methodcalllog` table. This adds a GC which should keep the table at a more manageable size in the future.
You can safely delete all data older than 30 days from this table, although you should do it by `id` instead of `dateCreated` since there's no key on `dateCreated` until this patch.
Test Plan:
- Ran GC.
- Looked at log UI.
- Ran Conduit methods.
Reviewers: btrahan
Reviewed By: btrahan
CC: wez, aran
Differential Revision: https://secure.phabricator.com/D6332