xz --flush-timeout=2000, old version:
1. xz is started. The next flush will happen after two seconds.
2. No input for one second.
3. A burst of a few kilobytes of input.
4. No input for one second.
5. Two seconds have passed and flushing starts.
The first second counted towards the flush-timeout even though
there was no pending data. This can cause flushing to occur more
often than needed.
xz --flush-timeout=2000, after this commit:
1. xz is started.
2. No input for one second.
3. A burst of a few kilobytes of input. The next flush will
happen after two seconds counted from the time when the
first bytes of the burst were read.
4. No input for one second.
5. No input for another second.
6. Two seconds have passed and flushing starts.
This switches units from microseconds to milliseconds.
New clock_gettime(CLOCK_MONOTONIC) will be used if available.
There is still a fallback to gettimeofday().